NX-920G

General Features
15W (806-870 MHz) RF Power Output
260 CH-GID / 128 Zones
10 Character Alphanumeric Aliases
Backlit LCD & Keys
Function / Status LCD Icons
Transmit / Busy / Call Alert / Warn LED
Blue Function / Status LED
On / Off Power Control
4 Up / Down Selectors
6 Front PF Keys
Emergency / AUX Key
4W Speaker Audio
Zone / CH Number Voice Announcement
DB-15 Accessory Connector
6 Programmable AUX I / Os
KPG-141D Windows® FPU
Flash Firmware Upgrading
MIL-STD-810 C/D/E/F/G
IP54 Water & Dust Intrusion
PC Serial Interface
SDM Manual Input*1
Transparent Data Mode*1
Built-in GPS Receiver Model: NX-920G
Available (Optional KRA-40G GPS Active
Antenna required for GPS functions)

Digital-General
NXDN® Digital Air Interface
AMBE+2™ VOCODER
6.25 & 12.5 kHz Channels
Over-the-Air Alias
Over-the-Air Programming*2
Paging Call
Emergency Call
All Group Call
Status Messaging*1
Remote Stun / Kill*1
Remote Check*1
Short & Long Data Messages*1
GPS Location with Voice*1
NXDN® Scrambler Included

Digital-Conventional Mode
64 Radio Access Numbers (RAN)
Individual & Group Selective Call
Mixed FM / Digital Operation
Conventional IP Networks
Site Roaming

Digital-Trunkking Mode
Individual Private Call
Group Call & Broadcast Call
Telephone Interconnect*3
Transmission Trunked Mode*3
Message Trunked Mode*3
Call Queuing with Priority*3
Late Entry (UID & GID)*3
4 Priority Monitor ID’s*3
Remote Group Add*1
Failsoft Mode

Multi-Site IP Network Compatible
60,000 GIDs / UIDs
Wide Area Group Call
Auto Roaming Registration
Group Registration

Multi-System Compatible
8 Trunked Networks*4
UID Lists for Each Network

SCAN
Single Zone / Multi-Zone / List Scan
Single Priority Scan (Conventional)

FM Modes-General
25 & 12.5 kHz Channels
NPSPAC Channels
Conventional & LTR® Zones
FleetSync® / II, MDC-1200, DTMF
QT / DQT (Conventional Zones Only)
Voice Inversion Scrambler (16 Codes)

FleetSync ® / II (FM)
PTT ID ANI / Caller ID
Selective / Group Call
Emergency, Status & Test Messages*1

MDC-1200
PTT ID ANI / Caller ID*3
Emergency, Radio Check & Inhibit
*1 Requires NX subscriber unit PC Serial Interface compatible software application
(e.g KENWOOD AVL & Dispatch Messaging software) or hardware (e.g. console).
*2 Requires KENWOOD OTAP Management software.
*3 These trunked features are primarily for system programming and operational dependent.
Priority Monitor also requires NX subscriber settings.
*4 Up to 8 different Trunked Networks can be configured per radio (each in a zone).

KMC-35
Microphone

KMC-36
Keypad Microphone(12-key)

KMC-30
Microphone

KMC-32
16-key Keypad Microphone(16-key)

KMC-53
Desktop Microphone

KMC-9C
Desktop Microphone

KES-3
External Speaker

KES-5
External Speaker

KMB-10
Key Lock Adapter

KLF-2
Line Filter

KCT-18
Ignition Sense Cable (requires KCT-60 option)

KCT-36
3m Extension Cable (for KCT-60)

KCT-60
Connection Cable

KRA-40G
GPS Active Antenna (required for GPS functions featured on the NX-920G)

Brochures

NX-920G

  NX-920
GENERAL
Frequency Range Receive 851 – 870 MHz
Transmit 806 – 825, 851 – 870 MHz
Number of Channels 260 ch
Zones 128 zone
Max. Channels per Zone 250 ch
Channel Spacing Analog 12.5 / 25 kHz
Digital 6.25 / 12.5 kHz
Operating Voltage 13.6 V DC ± 15%
Operating Temperature Range -30° C to +60° C
Frequency Stability ± 1.0 ppm
Antenna Impedance 50 Ω
Dimensions (W x H X D)
Projection not included
160 x 43 x 136 mm
Weight (net) 1.25 kg
RECEIVER
Sensitivity Digital @ 6.25 kHz (3% BER) 0.20 μV
Digital @ 12.5 kHz (3% BER) 0.28 μV
Analog (12 dB SINAD) 0.25 μV
Selectivity Analog @ 25 kHz 75 dB
Analog @ 12.5 kHz 65 dB
Intermodulation Distortion Analog 75 dB
Spurious Response Analog 75 dB
Audio Distortion Less than 3%
Audio Output 4 W / 4 Ω
TRANSMITTER
RF Power Output 5 – 15 W
Spurious Response 70 dB
FM Hum & Noise Analog @ 25 kHz 45 dB
Analog @ 12.5 kHz 40 dB
Audio Distortion Less than 3%
Modulation 16K0F3E, 14K0F3E, 11K0F3E, 8K30F1E,
8K30F1D, 8K30F7W, 4K00F1E,
4K00F1D, 4K00F7W, 4K00F2D

Accuracy specs are for long-term tracking (95th percentile values > 5 satellites visible at a nominal -130 dBm signal strength).

Analog measurements made per TIA/EIA 603 and specifications shown are typical.
Specifications are subject to change without notice, due to advancements in technology.

FleetSync® is a registered trademark of JVC KENWOOD Corporation.
LTR® is a registered trademark of Transcrypt International.
AMBE+2™ is a trademark of Digital Voice Systems Inc.
Windows® is a registered trademark of Microsoft Corporation.
NXDN® is a registered trademark of JVC KENWOOD Corporation and Icom Inc.
NEXEDGE® is a registered trademark of JVC KENWOOD Corporation.

Applicable MIL-STD & IP

MIL Standard MIL 810C
Methods/
Procedures
MIL 810D
Methods/
Procedures
MIL 810E
Methods/
Procedures
MIL 810F
Methods/
Procedures
MIL 810G
Methods/
Procedures
Low Pressure 500.1/
Procedure I
500.2/
Procedure I, II
500.3/
Procedure I, II
500.4/
Procedure I, II
500.5/
Procedure I, II
High Temperature 501.1/
Procedure I, II
501.2/
Procedure I, II
501.3/
Procedure I, II
501.4/
Procedure I, II
501.5/
Procedure I, II
Low Temperature 502.1/
Procedure I
502.2/
Procedure I, II
502.3/
Procedure I, II
502.4/
Procedure I, II
502.5/
Procedure I, II
Temperature Shock 503.1/
Procedure I
503.2/
Procedure I
503.3/
Procedure I
503.4/
Procedure I, II
503.5/
Procedure I
Solar Radiation 505.1/
Procedure I
505.2/
Procedure I
505.3/
Procedure I
505.4/
Procedure I
505.5/
Procedure I
Rain 506.1/
Procedure I, II
506.2/
Procedure I, II
506.3/
Procedure I, II
506.4/
Procedure I, III
506.5/
Procedure I, III
Humidity 507.1/
Procedure I, II
507.2/
Procedure II, III
507.3/
Procedure II, III
507.4 507.5/
Procedure II
Salt Fog 509.1/
Procedure I
509.2/
Procedure I
509.3/
Procedure I
509.4 509.5
Dust 510.1/
Procedure I
510.2/
Procedure I
510.3/
Procedure I
510.4/
Procedure I, III
510.5/
Procedure I
Vibration 514.2/
Procedure VIII, X
514.3/
Procedure I
514.4/
Procedure I
514.5/
Procedure I
514.6/
Procedure I
Shock 516.2/
Procedure I, II, III, V
516.3/
Procedure I, IV, V
516.4/
Procedure I, IV , V
516.5/
Procedure I, IV, V
516.6/
Procedure I, IV, V
International Protection Standard
Dust & Water Protection IP54: Radio itself

To meet MIL-810 and IP grade, microphone and cover for the D-sub15 and SP connector have to be connected. (Do not use the KCT cable and/or SP cable.)